Gill Instruments – MetPak RG – Proff værstasjon med puls inngang for nedbør: Temperatur Fuktighet Barometer Duggpunkt Modbus RTU
Modell: MetPak RG
Produsent: Gill Instruments

The MetPak RG Station features an on-board barometric pressure sensor and Rotronic Hygroclip temperature/humidity probe, with an additional input for a tipping bucket rain gauge (Gill tipping bucket rain gauge optionally available). This variant of the MetPak RG features the addition of an integrated WindSonic ultrasonic wind sensor for wind speed and direction measurement, and tipping bucket rain gauge for precipitation measurement.
The design of the MetPak RG allows all measurements to be as accurate as possible without influencing other measured parameters yet provides a complete, compact, reference quality system. The unit is especially suitable for harsh, coastal and fixed marine platforms where accuracy of the precipitation measurements is paramount and is supplied with selectable Gill ASCII, NMEA SDI-12 and Modbus outputs.
NOTE: Specifications relate to MetPak RG with Integrated WindSonic and Rain Gauge |
Wind Measurement | |
Parameters | Wind speed & direction or U & V (Vectors) |
Units of measure | m/s, knots, mph, kph, ft/min |
Wind Speed Range | 0-60m/s (134 mph) |
Wind Speed Accuracy | ±2% @12m/s |
Wind Speed Resolution | 0.01m/s (0.02 mph) |
Wind Direction Range | 0 to 359º – No dead band |
Wind Direction Accuracy | ±3º @12m/s |
Wind Direction Resolution | 1º |
Air Temperature | |
Air Temperature | Pt100 1/3 Class B |
Range | -50ºC to 100ºC |
Accuracy | ±0.1ºC |
Resolution | 0.1ºC (0.1ºF) |
Units of measure | ºC or ºF |
Relative Humidity | |
Range | 0-100% RH |
Accuracy | ±0.8% @23ºC |
Resolution | 0.1% RH |
Units of measure | % RH |
Compensated for temperature dependency | |
Barometric Pressure | |
Range | 600-1100hPa |
Accuracy | ±0.5hPa |
Resolution | 0.1hPa |
Units of measure | hPa, mbar, mmHg, inHg |
Compensated for temperature dependency -30ºC to 70ºC | |
Dew Point | |
Resolution | 0.1ºC (0.1ºF) |
Units of measure | ºC or ºF |
Accuracy | ±0.15ºC (23ºC ambient temp @20ºC dew point) |
Precipitation | |
Measurement Concept | Aerodynamic Tipping Bucket Rain Gauge |
Range | Effectively Unlimited |
Resolution | 0.2mm |
Units of measure | mm per tip |
Accuracy | ±2% |
Power Supply | |
Input voltage | 5V to 30V |
Current | <16mA (Output 1 second) @12V |
SDI-12 | |
Input Voltage | 12V nominal (9.6-16V) |
Current | <6.5mA Low power operation |
Outputs | |
Digital outputs | RS232, RS422, RS485*, SDI-12 or MODBUS (user selectable) |
Baud rates | 4800-57600 (ASCII) or 1200 (SDI-12) |
Protocols | ASCII, SDI-12 V1.3 |
Data output | 1s, 2s, 4s or polled mode |
*2 wire point to point | |
Environmental | |
Protection class | IP65 |
EMC | EN 61326 |
Operating temperature | -35ºC to 70ºC |
Storage temperature | -40ºC to 80ºC |
Operating humidity | 0% to 100% humidity |
Mechanical | |
External construction | UV stabilised white thermoplastic |
Fittings | Anodised Aluminium bracket to allow fitting to 30mm to 58mm mast dimensions |
Weight | 2.1kg (including bracket) |
Software | |
MetView | Free software for the display of data and logging |
MetSet | Free software for the configuration of the MetPak, MetPak RG & MetPak Pro |
Optional Accessories | |
Cables | 15m Power & Data cable USB configuration cable |
Hardware | Heater Interface Box |
MetSet | |
Under kan du finne nyttige dokumenter for produktet: