Description
From the WS product family of professional intelligent measurement transducers with digital interface for environmental applications.
Supplementary description
WS501-UMB Smart Weather Sensor for measuring of air temperature, relative humidity, solar radiation, air pressure, wind direction and wind speed. Relative humidity is measured by means of a capacitive sensor element; a precision NTC measuring element is used to measure air temperature. The world renowned technology of Kipp Zonen CMP3 is integrated. Ultrasonic sensor technology is used to take wind measurements. Measurement output can be accessed by the following protocolls: UMB-Binary, UMB-ASCII, SDI-12, MODBUS. One external temperature or rain sensor is connectable.
Special features:
- All in One
- Aspirated temperature/humidity measurement
- Open communication protocol:
- UMB-ASCII
- UMB-Binary
- SDI-12
- MODBUS
- Analoge outputs in combination with 8160.UDAC
- Third-Party-Rain gauge sensors are compatible: 0.1mm, 0.2mm, 0.5mm, 1mm heated and unheated.
Temperature | |
Principle | NTC |
Measuring Range | -50…60°C |
Accuracy | ±0,2°C (-20°C… 50°C), otherwise ±0.5°C (>-30°C) |
Relative Humidity | |
Principle | Capacitive |
Measuring Range | 0…100% RH |
Accuracy | ±2% RH |
Radiation | |
Response time (95%) | < 18s |
Non-stability (change/year) | < 1% |
Non-linearity (0 to 1,000 W/m²) | < 1% |
Directional error (at 80° with 1,000W/m²) | < 20W/m² |
Temperature dependence of sensitivity | < 5% (-10 to 40°C) |
Tilt error (at 1000W/m²) | < 1% |
Spectral range (50% points) | 300 to 2,800nm |
Measuring range | 1400 W/m² |
Air Pressure | |
Principle | MEMS Capacitive |
Measuring Range | 300…1200 hPa |
Accuracy | /-0.5 hPa (0… 40°C) |
Wind Direction | |
Principle | Ultrasonic |
Measuring Range | 0…359.9° |
Accuracy | <3° RMSE >1.0m/s |
Wind Speed | |
Principle | Ultrasonic |
Measuring Range | 0…60m/s |
Accuracy | ±0.3m/s or ±3% (0…35m/s) RMS of reading, whichever is greater ±5% (>35m/s) RMS |
General Information | |
Heating | 20VA at 24VDC |
Protection type housing | IP66 |
Interface | RS485, 2-wire, half-duplex |
Operating Power Consumption | 24VDC /- 10% |
Operating Humidity Range | 0…100% |
Operating Temperature Range | -50…60%°C |
Under kan du finne nyttige dokumenter for produktet: