Skip to content

Gill Instruments – MetPak RG – Proff værstasjon med puls inngang for nedbør: Temperatur Fuktighet Barometer Duggpunkt Modbus RTU

Modell: MetPak RG
Produsent: Gill Instruments

Varenummer: 3991 Kategori:
Bjørn Cato Solli 2

Bjørn Cato Solli

Luft og miljø
22 09 40 54
The MetPak RG Station features an on-board barometric pressure sensor and Rotronic Hygroclip temperature/humidity probe, with an additional input for a tipping bucket rain gauge (Gill tipping bucket rain gauge optionally available). This variant of the MetPak RG features the addition of an integrated WindSonic ultrasonic wind sensor for wind speed and direction measurement, and tipping bucket rain gauge for precipitation measurement.
The design of the MetPak RG allows all measurements to be as accurate as possible without influencing other measured parameters yet provides a complete, compact, reference quality system. The unit is especially suitable for harsh, coastal and fixed marine platforms where accuracy of the precipitation measurements is paramount and is supplied with selectable Gill ASCII, NMEA SDI-12 and Modbus outputs.

 

Selger Bjørn Cato Solli
NOTE: Specifications relate to MetPak RG with Integrated WindSonic and Rain Gauge
Wind Measurement
Parameters Wind speed & direction or U & V (Vectors)
Units of measure m/s, knots, mph, kph, ft/min
Wind Speed Range 0-60m/s (134 mph)
Wind Speed Accuracy ±2% @12m/s
Wind Speed Resolution 0.01m/s (0.02 mph)
Wind Direction Range 0 to 359º – No dead band
Wind Direction Accuracy ±3º @12m/s
Wind Direction Resolution
Air Temperature
Air Temperature Pt100 1/3 Class B
Range -50ºC to 100ºC
Accuracy ±0.1ºC
Resolution 0.1ºC (0.1ºF)
Units of measure ºC or ºF
Relative Humidity
Range 0-100% RH
Accuracy ±0.8% @23ºC
Resolution 0.1% RH
Units of measure % RH
Compensated for temperature dependency
Barometric Pressure
Range 600-1100hPa
Accuracy ±0.5hPa
Resolution 0.1hPa
Units of measure hPa, mbar, mmHg, inHg
Compensated for temperature dependency -30ºC to 70ºC
Dew Point
Resolution 0.1ºC (0.1ºF)
Units of measure ºC or ºF
Accuracy ±0.15ºC (23ºC ambient temp @20ºC dew point)
Precipitation
Measurement Concept Aerodynamic Tipping Bucket Rain Gauge
Range Effectively Unlimited
Resolution 0.2mm
Units of measure mm per tip
Accuracy ±2%
Power Supply
Input voltage 5V to 30V
Current <16mA (Output 1 second) @12V
SDI-12
Input Voltage 12V nominal (9.6-16V)
Current <6.5mA Low power operation
Outputs
Digital outputs RS232, RS422, RS485*, SDI-12 or MODBUS (user selectable)
Baud rates 4800-57600 (ASCII) or 1200 (SDI-12)
Protocols ASCII, SDI-12 V1.3
Data output 1s, 2s, 4s or polled mode
*2 wire point to point
Environmental
Protection class IP65
EMC EN 61326
Operating temperature -35ºC to 70ºC
Storage temperature -40ºC to 80ºC
Operating humidity 0% to 100% humidity
Mechanical
External construction UV stabilised white thermoplastic
Fittings Anodised Aluminium bracket to allow fitting to 30mm to 58mm mast dimensions
Weight 2.1kg (including bracket)
Software
MetView Free software for the display of data and logging
MetSet Free software for the configuration of the MetPak, MetPak RG & MetPak Pro
Optional Accessories
Cables 15m Power & Data cable USB configuration cable
Hardware Heater Interface Box
MetSet