Skip to content

Lufft – WS510 – Værstasjon WS510

Modell: WS510
Produsent: Lufft

Varenummer: 4621 Kategorier: ,
Lufft - WS510 - Værstasjon WS510 2

Bjørn Cato Solli

Luft og miljø
22 09 40 54

Description

From the WS product family of professional intelligent measurement transducers with digital interface for environmental applications.

Supplementary description

WS510-UMB Smart Weather Sensor for measuring of air temperature, relative humidity, solar radiation, air pressure, wind direction and wind speed. Relative humidity is measured by means of a capacitive sensor element; a precision NTC measuring element is used to measure air temperature. The world renowned technology of Kipp Zonen CMP10 is integrated. Ultrasonic sensor technology is used to take wind measurements. Measurement output can be accessed by the following protocolls: UMB-Binary, UMB-ASCII, SDI-12, MODBUS. One external temperature or rain sensor is connectable.

Special features

  • First All in One weather sensor with ISO9060: secondary standard pyranometer
  • Aspirated temperature/humidity measurement
  • Open communication protocol
  • UMB-ASCII
  • UMB-Binary
  • SDI-12
  • MODBUS
  • Analoge outputs in combination with 8160.UDAC
  • Third-Party-Rain gauge sensors are compatible: 0.1mm, 0.2mm, 0.5mm, 1mm heated and unheated.
Selger Bjørn Cato Solli
Temperature
Principle NTC
Measuring Range -40…80°C
Accuracy ±0,2°C (-20°C… 50°C), otherwise ±0.5°C (>-30°C)
Relative Humidity
Principle Capacitive
Measuring Range 0…100% RH
Accuracy ±2% RH
Radiation
Response time (95%) < 1s
Spectral range 300 to 1100nm
Measuring range 1400W/m²
Air Pressure &
Principle MEMS Capacitive
Measuring Range 300…1200 hPa
Accuracy /-0.5 hPa (0… 40°C)
Wind Direction
Principle Ultrasonic
Measuring Range 0…359.9°
Accuracy <3° RMSE >1.0m/s
Wind Speed
Principle Ultrasonic
Measuring Range 0…75m/s
Accuracy ±0.3m/s or ±3% (0…35m/s) RMS of reading, whichever is greater ±5% (>35m/s) RMS
General Information
Heating 20VA at 24VDC
Protection type housing IP66
Interface RS485, 2-wire, half-duplex
Operating Power Consumption 12-24 VDC ±10%
Operating Humidity Range 0…100%
Operating Temperature Range -40…80%°C

Fyll ut skjemaet under for å få tilgang til utvidet dokumentasjon.