Skip to content

Lufft – ARS31Pro-UMB – Frysepunktsmåler for vei m/temperatursensor

Modell: ARS31Pro-UMB
Produsent: Lufft

Varenummer: 4997 Kategori:
Lufft - ARS31Pro-UMB - Frysepunktsmåler for vei m/temperatursensor 3

Bjørn Cato Solli

Luft og miljø
22 09 40 54

The active ARS31Pro-UMB sensor is flush-mounted in the road or runway surface and measures the freezing temperature by means of active cooling and heating of the sensor surface. through this, it’s indepented from the de-icing material. In addition it measures the road surface temperature. This surface temperature sensor is integrated into a second housing which is connected with the ARS31Pro-UMB. The distance between the two housings is 50 cm. One additional measurement is carried out in order to find out critical conditions in the next few hours. This early alert message delivers extra road surface condition information in addition to the real time road conditions. The two-section housing design allows the combined electronics unit to be removed for maintenance purposes at any time, in just a few minutes. In conjunction with the interface converter 8160.UISO, the sensor can be built into new and existing UMB networks. The sensors are addressable and can be networked.

Road surface temperature, freezing point

ctive cooling and heating (Peltier element), NTC (road surface temp.)

Two part housing design allows easy maintenance/re-calibration, low energy consumption allows solar operation, freezing point determined independently from de-icing material

Advantages

  • Replaceable sensor/electronics
  • Simulation of critical surface conditions in the avery near future
  • All-in-one sensor including active measurement of freeze point temperature
  • Mixture-independent measurement
  • Analog outputs in combination with 8160.UDAC

 

Selger Bjørn Cato Solli
General
Dimensions Ø 120mm, height 50mm
Weight Approx. 1100g
Storage temperature -40…70°C (in packaging)
Protection type IP68
Power supply 24 VDC ±10%
Connector CAGE CLAMP, WAGO, (cross-section <0.5mm²)
Operating temperature -40…80°C
Operating rel. humidity 0…100% RH
Power consumption Approx. 30 W
Interface RS485, baud rate: 2,400…38,400 bit/s (default: 19,200),
Cable length 50m
External road surface temperature
Principle NTC
Measuring range -40 … 80 °C
Unit °C
Accuracy ±0.2°C (-10…10°C), or ±0.5°
Resolution 0.1
Freezing point
Measuring range -40 … 0 °C
Unit °C
Accuracy > -15°C ±0,5°C for Tg > -15°C (with NaCI, determined according to CEN/TS 15518-4);
Accuracy < -15°C ±1,5°C for Tg < -15°C (with NaCI, determined according to CEN/TS 15518-4)